Browsing by Author "Castro MDM"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Pulmonary Tuberculosis Detection with MiniDock MTB Using Swab Samples.(2026-Apr-30) Yerlikaya S; Chirwa M; Ajide B; Castro MDM; Ha H; Kato-Maeda M; Kisakye E; Marcelo D; Mochizuki T; Rockman L; Steadman A; Thangakunam B; Bimba JS; Christopher DJ; Muyoyeta M; Phan H; Theron G; Yu C; Kremer K; Phillips PPJ; Nahid P; Denkinger CM; Cattamanchi A; Andama ABACKGROUND: Improved diagnostic tools for tuberculosis that are suitable for use in peripheral health centers are essential for reducing the persistent gap between estimated and notified cases. The diagnostic accuracy and usability of the MiniDock MTB test for detecting pulmonary tuberculosis is unknown. METHODS: We conducted a prospective, cross-sectional study at outpatient centers in India, Nigeria, the Philippines, South Africa, Uganda, Vietnam, and Zambia. Patients 12 years of age or older with presumptive pulmonary tuberculosis were enrolled between September 12, 2024, and March 31, 2025. Assessment with MiniDock MTB was performed with sputum swabs and tongue swabs. Diagnostic accuracy was evaluated against a sputum-culture-based reference and as compared with sputum-smear microscopy and Xpert MTB/RIF Ultra assay. Usability was assessed with a system usability scale and direct observation. RESULTS: A total of 1380 participants were enrolled; 255 (18.5%) had human immunodeficiency virus infection and 226 (16.4%) had culture-confirmed tuberculosis. MiniDock MTB sensitivity was 85.7% (95% confidence interval [CI], 80.4 to 90.0) with sputum and 79.6% (95% CI, 73.8 to 84.7) with tongue swabs; specificity was greater than 97.5% for both. Results of sputum tests with MiniDock MTB closely matched those with Xpert MTB/RIF Ultra for sensitivity (difference, -2.8 percentage points; 95% CI, -6.0 to 0.5). MiniDock MTB had greater sensitivity than smear microscopy for tests of sputum (difference, 24.3 percentage points; 95% CI, 17.9 to 30.7) and tongue swabs (difference, 18.3 percentage points; 95% CI, 12.0 to 24.7). The test showed diagnostic accuracy that was consistent with World Health Organization (WHO) accuracy targets for near-point-of-care tuberculosis diagnostics (≥85% sensitivity for sputum and ≥75% for nonsputum and ≥98% specificity for both). The median score on the system usability scale (range, 0 to 100, with higher scores indicating better perceived usability) was 75 (interquartile range, 65 to 80), which indicated good usability. No adverse events related to the index test were reported. CONCLUSIONS: MiniDock MTB met WHO targets for diagnostic accuracy and usability for tuberculosis detection across diverse clinical settings. (Funded by the National Institutes of Health and others; Rapid Research in Diagnostics Development for TB Network and Assessing Diagnostics at Point-of-Care for Tuberculosis ClinicalTrials.gov numbers, NCT04923958 and NCT05941052.).Item User perspectives and preferences on a novel TB LAM diagnostic (Fujifilm SILVAMP TB LAM)-a qualitative study in Malawi and Zambia.(2022) Herrmann Y; Lainati F; Castro MDM; Mwamba CP; Kumwenda M; Muyoyeta M; Broger T; Heinrich N; Olbrich L; Corbett EL; McMahon SA; Engel N; Denkinger CMWidely available tuberculosis (TB) diagnostics use sputum samples. However, many patients, particularly children and patients living with HIV (PLHIV), struggle to provide sputum. Urine diagnostics are a promising approach to circumvent this challenge while delivering reliable and timely diagnosis. This qualitative study in two high TB/HIV burden countries assesses values and preferences of end-users, along with potential barriers for the implementation of the novel Fujifilm SILVAMP TB-LAM (FujiLAM, Fujifilm, Japan) urine test. Between September 2020 and March 2021, we conducted 42 semi-structured interviews with patients, health care providers (HCPs) and decision makers (DMs) (e.g., in national TB programs) in Malawi and Zambia. Interviews were transcribed verbatim and analyzed using a framework approach supported by NVIVO. Findings aligned with the pre-existing Health Equity Implementation Framework, which guided the presentation of results. The ease and convenience of urine-based testing was described as empowering among patients and HCPs who lamented the difficulty of sputum collection, however HCPs expressed concerns that a shift in agency to the patient may affect clinic workflows (e.g., due to less control over collection). Implementation facilitators, such as shorter turnaround times, were welcomed by operators and patients alike. The decentralization of diagnostics was considered possible with FujiLAM by HCPs and DMs due to low infrastructure requirements. Finally, our findings support efforts for eliminating the CD4 count as an eligibility criterion for LAM testing, to facilitate implementation and benefit a wider range of patients. Our study identified barriers and facilitators relevant to scale-up of urine LAM tests in Malawi and Zambia. FujiLAM could positively impact health equity, as it would particularly benefit patient groups currently underserved by existing TB diagnostics. Participants view the approach as a viable, acceptable, and likely sustainable option in low- and middle-income countries, though adaptations may be required to current health care processes for deployment. Trial registration: German Clinical Trials Register, DRKS00021003. URL: https://www.drks.de/drks_web/setLocale_EN.do.
