Repository logo
Communities & Collections
All of CIDRZ Publications
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Jacobs BKM"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    Item
    A Prospective Evaluation of the Diagnostic Accuracy of the Point-of-Care VISITECT CD4 Advanced Disease Test in 7 Countries.
    (2025-Feb-04) Gils T; Hella J; Jacobs BKM; Sossen B; Mukoka M; Muyoyeta M; Nakabugo E; Van Nguyen H; Ubolyam S; Macé A; Vermeulen M; Nyangu S; Sanjase N; Sasamalo M; Dinh HT; Ngo TA; Manosuthi W; Jirajariyavej S; Denkinger CM; Nguyen NV; Avihingsanon A; Nakiyingi L; Székely R; Kerkhoff AD; MacPherson P; Meintjes G; Reither K; Ruhwald M; School of Health and Wellbeing, University of Glasgow, Glasgow, United Kingdom.; German Centre for Infection Research, Heidelberg University Hospital, Heidelberg, Germany.; Viet Tiep Hospital, Hai Phong, Viet Nam.; Bamrasnaradura Infectious Diseases Institute, Nonthaburi, Thailand.; National Lung Hospital, Ha Noi, Viet Nam.; Taksin Hospital, Bangkok, Thailand.; Global Health Institute, University of Antwerp, Wilrijk, Belgium.; Department of Clinical Sciences, Institute of Tropical Medicine, Antwerp, Belgium.; Department of Medicine, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa.; University of Basel, Basel, Switzerland.; Public Health Group, Malawi-Liverpool-Wellcome Programme, Blantyre, Malawi.; Ifakara Health Institute, Dar es Salaam, Tanzania.; Wellcome Centre for Infectious Diseases Research in Africa, Institute of Infectious Disease and Molecular Medicine, University of Cape Town, Cape Town, South Africa.; Division of HIV, Infectious Diseases and Global Medicine, Zuckerberg San Francisco General Hospital and Trauma Center, University of California, San Francisco, San Francisco, California, USA.; Clinical Research Unit, Swiss Tropical and Public Health Institute, Allschwil, Switzerland.; Department of Pathology, Kamuzu University of Health Sciences, Blantyre, Malawi.; HIV Netherlands Australia Thailand Research Collaboration, Thai Red Cross AIDS Research Centre and Center of Excellence in Tuberculosis, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.; Foundation for Innovative New Diagnostics, the Global Alliance for Diagnostics, Geneva, Switzerland.; Clinical Research Department, London School of Hygiene and Tropical Medicine, London, United Kingdom.; Division of Infectious Disease and Tropical Medicine, Heidelberg University Hospital and Faculty of Medicine, Heidelberg University, Heidelberg, Germany.; Infectious Diseases Institute, Makerere University, Kampala, Uganda.; Centre for Infectious Disease Research in Zambia, Lusaka, Zambia.; CIDRZ; Centre for Infectious Disease Research in Zambia (CIDRZ)
    BACKGROUND: CD4 measurement is pivotal in the management of advanced human immunodeficiency virus (HIV) disease. VISITECT CD4 Advanced Disease (VISITECT; AccuBio, Ltd) is an instrument-free, point-of-care, semiquantitative test allowing visual identification of CD4 ≤ 200 cells/µL or >200 cells/ µL from finger-prick or venous blood. METHODS: As part of a diagnostic accuracy study of FUJIFILM SILVAMP TB LAM, people with HIV ≥18 years old were prospectively recruited in 7 countries from outpatient departments if a tuberculosis symptom was present, and from inpatient departments. Participants provided venous blood for CD4 measurement using flow cytometry (reference standard) and finger-prick blood for VISITECT (index text), performed at point-of-care. Sensitivity, specificity, and positive and negative predictive values of VISITECT to determine CD4 ≤ 200 cells/ µL were evaluated. RESULTS: Among 1604 participants, the median flow cytometry CD4 was 367 cells/µL (interquartile range, 128-626 cells/µL) and 521 (32.5%) had CD4 ≤ 200 cells/µL. VISITECT sensitivity was 92.7% (483/521; 95% confidence interval [CI], 90.1%-94.7%) and specificity was 61.4% (665/1083; 95% CI, 58.4%-64.3%). For participants with CD4 0-100, 101-200, 201-300, 301-500, and >500 cells/µL, VISITECT misclassified 4.5% (95% CI, 2.5%-7.2%), 12.5 (95% CI, 8.0%-18.2%), 74.1% (95% CI, 67.0%-80.5%), 48.0% (95% CI, 42.5%-53.6%), and 22.6% (95% CI, 19.3%-26.3%), respectively. CONCLUSIONS: VISITECT's sensitivity, but not specificity, met the World Health Organization's minimal sensitivity and specificity threshold of 80% for point-of-care CD4 tests. VISITECT's quality needs to be assessed and its accuracy optimized. VISITECT's utility as CD4 triage test should be investigated. Clinical Trials Registration. NCT04089423.

CIDRZ copyright © 2025

  • Privacy policy
  • End User Agreement
  • Send Feedback